Join Engormix and be part of the largest agribusiness social network in the world.
See:
Participation in Forum on June 29, 2011
As I have previous said and also my friend Dr. Muhammad Arshad has indicated the only solution is to increase the speed of air replacement in the shed. This can only be done by increasing the fan speed or putting in more fans to replace the humid air at a faster speed. The method of air conditioning and other solutions put forward by my other friends are only practical in house and theatres but n ...
0
Participation in Forum on June 28, 2011
Dr. Munawer I would suggest that you just try to increase the air flow upto 4 m/sec by increasing the fan speed which you can do by increasing the drive pulley size or decreasing the pulley size of the fan shaft. It is worth giving it a try. I had tried this and it worked very well.
0
Participation in Forum on June 28, 2011
With Tunnel ventilation system you cannot avoid the humidity outside the shed. With increased air flow through the shed you can replace the humid air inside the shed and this is the only solution. If somebody has a bright idea then he can come up with it rather not just critising and not giving any solution.
1
Participation in Forum on June 28, 2011
There is term called "Tunnel Effect" .This effect is caused by increasing the speed of wind passing through the poultry shed. This can only be achieved by blocking all the opening on the sides of the shed and the only air passage is the cooling pads. When humidity is high the only solution is by increasing air speed through the shed. If you want any help do call me on my cell.
1
Participation in Forum on June 28, 2011
You can get good result by increasing the fan speeds by changing the pulley on the motor shaft. Can you give me the diameter of both the pulleys i.e the motor side and the fan side and also the RPM of the motors then I guide you how much to change in the pulley is to be made. Cell # 0300-8461046
0
Participation in Forum on June 28, 2011
Dr. Munawer, what is the actual problem you are facing while running your farm on evaporative cooling system. The only problem I faced while at the Be Be Jan Farms was that the air speed inside the shed was very slow with the original system supplied by the company in USA. as a result the birds were uncomfortable due to humidity and wet litter. The air speed inside the shed was 200 m/sec measure w ...
3
Participation in Forum on May 10, 2011
The use of sulphaquinoxiline in water is an outdated practice. You should check in the market some new drugs which are very useful in controlling coccidiosis. Regarding the use of Clopidol in feed I would suggest that you check the dosage being used. Because normally the feed manufacturers are very reluctant to use proper dosage of anti-coccidiostat to save money and the result is that the Emiria ...
0
Participation in Forum on February 24, 2011
I would like to know the source these bulbs so that the same can be marketed in the industry which can result in hugh saving for the poultry farmer.
0
Participation in Forum on February 24, 2011
Where can I find the latest nutrient requirements of Broilers, breeders and laying birds? Also the charts of nutrient analysis of differents ingredients used in formulating the poultry diet.
0
Participation in Forum on June 30, 2010
The author of the article has given an idea which is not practically possible to apply in the brooding of poultry chicks. Suppose somebody put this in the shed what about the litter being scattered by the chicks and burning their feet on the hot metal sheets. The author should first read some material about brooding technics and then start given such novel ideas. I have an experience of more than ...
0
equalizer Statistics: Forums(10)