Target Temperature Changes with Heating System Type

Published: October 5, 2022
Summary
The house has been preheated for 36 hours to 92°F. The chicks will be arriving in a few hours and the controller’s six temperature sensors (positioned one foot above the floor) indicate the air temperature is between 91 and 92°F (Figure 2). A thermal image indicates the floor temperature is between 87 and 102°F (Figure 1) There is no measurable ammonia due to the fact that li...