Explore

Advertise on Engormix

Target Temperature Changes with Heating System Type

Published: October 5, 2022
Summary
The house has been preheated for 36 hours to 92°F. The chicks will be arriving in a few hours and the controller’s six temperature sensors (positioned one foot above the floor) indicate the air temperature is between 91 and 92°F (Figure 2). A thermal image indicates the floor temperature is between 87 and 102°F (Figure 1) There is no measurable ammonia due to the fact that li...
Related topics:
Authors:
Mike Czarick
Dr. Brian D. Fairchild
Influencers who recommended :
George Entz, Dr. Mehmet Kuran
Recommend
Comment
Share
Nisar Muhammad Khan
30 de mayo de 2026
Sir,
Very nice and informative column, understanding behavior of chicks will tell the story of the house temperature and keep close to chicks will understand their behavior .
Recommend
Reply
1
Profile picture
Would you like to discuss another topic? Create a new post to engage with experts in the community.
Featured users in Poultry Industry
Megan Koppen
Megan Koppen
United States
Kendra Waldbusser
Kendra Waldbusser
United States
Kim Litteken
Kim Litteken
Marketing and Customer Service Manager
United States