Facts on detection capabilities for X-ray systems based on chicken bone composition variations

Published: December 4, 2019
By: Joergen Rheinlaender, Ph.D. / CEO, InnospeXion ApS Denmark. www.innospexion.dk.
Introduction
This presentation provides an explanation of why some bones can be detected by X-ray inspection, whilst others cannot. It also highlights the effects and benefits of accessing the lower part of the X-ray spectrum during poultry bone detection. The testing of an X-ray system is typically based on selecting small bones and the cutting of small pieces of these bones. These cut bone pieces are subsequently placed into a chicken fillet or a deboned leg (meat) (the product). The product is subsequently scanned by the X-ray system, and its ability to detect the bone in question is assessed. However, a bone is not just a bone. The detectability of a bone depends on its calcification level. And the detection depends on the specific X-ray technology being used. Most important is the X-ray energy selection. At lower levels of X-ray energy and with longer wavelengths, i.e. below 30 kV, the contrast between bone and meat increases exponentially.
Revelations at the lower X-ray energy spectrum
X-ray systems for poultry bone detection typically works around 60-80 kV. The key reason is that the high energy is needed due to the sensitivity limitation of standard X-ray imaging detectors. This is unfortunate, since the contrast between bone and meat reduces exponentially with increasing energy. For some years, research in the medical and dental sector has brought new detectors with very good imaging characteristics down to 10 kV. These are very interesting for chicken bone detection, since the excellent contrast is matched with an excellent resolution. The detectors require a special long wavelength X-ray energy source which can provide a very high flux to ascertain a high signal-to-noise level. These developments have been tested for chicken and fish processing during the last 8 years, and provides crystal clear images of product irregularities, interfaced with auxiliary equipment for reject and sorting.
Quantification of a bone calcification level
The medical sector has worked with a quantification of tissue, bones, fluids etc for many years. This is due to using CT (computerized tomography) for medical diagnosis. The quantitative distinction is based on differences in X-ray attenuation using the so-called Hounsfield Unit (HU). This scale is based on water having the value of 0 HU, whereas air has the value -1000 HU. A calcified bone from e.g. pork is typically in the range 600-1000 HU (or beyond), whereas soft-bone (cartilage) is much lower (e.g. 100-250 HU), due to the lower abundance of calcium minerals (e.g. hydroxyapatite). For chicken, the bone HU value depends on the age of the chicken, its feeding, its breed, and many others. For chicken in general food production, an average HU is about 400-450 HU for calcified bone, but varying from the level of cartilage (soft-bone) (100-250 HU) up to 1000 HU for the larger and most calcified bone.
Facts on detection capabilities for X-ray systems based on chicken bone composition variations - Image 1
Fig. 1. A chicken wish bone with the typical HU values of the bone in different positions. Based on information from the Danish Meat Research Institute, DMRI.
Detection of chicken bones relative to the HU value of the bone
Since the detection of a bone depends on the HU value of the bone, it makes no sense to consider only the dimension when evaluating the bone detectability. A comparison of different X-ray systems must, therefore, be made with the exact same bone pieces. This is difficult, since practical conditions may cause loss of the (very small) bone pieces used. The optimal solution, therefore, is to apply a test sample with artificial bone pieces (made of a polymer with hydroxyapatite) with a HU value (i.e. around 400-450) as the average chicken bone.
Concluding remarks
The above analysis unveils that the comparison of different X-ray systems should be based on standardized test samples. It is also clear that quality control verifications of X-ray system detection capability (as performed e.g. on an hourly regular) must be based on well known, certified and calibrated test samples. It makes sense to use test samples with HU values in the range 400 to 450 HU, as these conform to the average range of calcified bones in general chicken production. By accessing the lower spectrum of X-ray energy and using longer wavelength X-rays, it is possible to detect bones around 1 mm, also in cases when the bones that are less calcified (lower HU values) these can be detected, even when much larger than 1 mm.